<LOGO>
FM Transmitter Measurement Report
Created: 2025-01-18 18-19-17
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 59 dBuV SANDELS
Pilot RDS Phase Difference
6.3 kHz 5.8 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
11 kHz 69 kHz 15690 14,3595
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
3,9 dBr 4,92 dBr 5,6 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
94.7 MHz -
FM Scope Max at: 69 kHz MIN: 11 kHz % above 76 kHz: 14,3595 Acquired: 2025/01/18 18.18.13 Total samples: 15690 Equivalent time: 0:13:04 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600
FM Scope MAX: 5,6 dBr MIN: 3,9 dBr AVE: 4,92 dBr % above 12,2 dBr: 0,0 Last value: 4,3 dBr (2025/01/18 18.18.12) 18.04 18.06 18.08 18.10 18.12 18.14 18.16 18.18 0 2 4 6 Pm [dBr]